Steel Foundations – BEAM
GroundPlug® BEAM
GroundPlug® Beam
Strong foundation for extra large design loads
THE GROUNDPLUG® BEAM FOUNDATION IS BASED ON A COMBINATION OF SEVERAL SIMPLE GROUNDPLUG® FOUNDATIONS OF THE TYPE SK, GP OR PILEXPRO CONNECTED TO EACH OTHER WITH A STEEL BEAM SYSTEM.
READ MORE ABOUT GROUNDPLUG SK/GP FOUNDATIONS.
READ MORE ABOUT GROUNDPLUG PILEXPRO FOUNDATIONS.
GroundPlug® Beam is an adaptable solution used for projects such as very large pylons, wind turbines, etc., where the required load capacity cannot be achieved with a single foundation. This may be due to terrain topography, underground installations and infrastructure, or poor soil conditions.
TECHNICAL DATA
Series | BEAM |
---|---|
Steel Grade | s235 / s355 |
Lengths | 1000 - 5000 mm |
Material | S235 Steel |
Treatment | Galvanised VFZ iht. ISO EN 1461 |
Capacity | 9 - 190 kN-m |

STANDARDISED PRODUCTS WHICH CAN BE INCLUDED IN A GROUNDPLUG® BEAM SOLUTION
Our engineering department employs qualified specialists with extensive experience and technical know-how. Our employees are specialised in various areas, enabling us to offer a wide range of services. We do everything from theoretical calculations, resource, time and financial planning to managing activities on the construction site.
In our work, we always emphasise good communication, both internally and with our customers and partners. For us, this is a prerequisite for a successful construction project that benefits from resource-saving planning and efficient management.
SK | GP | PILEXPRO |
---|---|---|
SK60TV1165-3165 | GP60TV1000-2000 | PP120/1500-4000 + EXT1000-4000 |
SK76TV2165-3165 | GP76TV2000-3000 | PP150/1500-4000 + EXT1000-4000 |
GP89TV3000 | PP175/1500-4000 + EXT1000-4000 | |
PP200/1500-4000 + EXT1000-4000 | ||
PP230/1500-4000 + EXT1000-4000 |
Strong Foundation
GroundPlug® Beam consists of several individual steel foundations on which a beam system is mounted. The foundation can thus be used for large design loads or in unfavourable soil conditions.
Quality & Precision
Like all our patented GroundPlug® products, the GroundPlug® Beam foundation is also protected against corrosion by means of a hot-dip galvanising process.

Different Areas of Focus
This type of foundation system is mainly used for stadium masts, wind turbines, large signs and pylons.
A Well-Known Project
GroundPlug® Beam system is designed for various customers worldwide of all sizes, including foundations for the Olympic signs in London in 2012, which were mounted on GroundPlug® foundations.
INSTALLATION
The GROUNDPLUG® BEAM FOUNDATION IS BASED ON A COMBINATION OF SEVERAL GROUNDPLUG® SK, GP OR PILEX FOUNDATIONS, WHICH ARE CONNECTED WITH STEEL BEAMS.
BEAM CASES
DOCUMENTATION
ALL STEEL FOUNDATIONS FROM GROUNDPLUG® ARE BASED ON CALCULATIONS IN ACCORDANCE WITH:
EN 1990, EN 1991-1-1, EN 1991-1-3, EN 1991-1-4,EN 1991-2, EN 1993-1-1, EN 1993-1-3, EN, 1993-1-5,EN 1993-1-8, EN 1993-1-9, EN 1993-5, EN 1997-1,EN 1997-2, EN 1794-1.
ANALYTICAL CALCULATIONS AND PRACTICAL TESTS:
- ASTM Standard Designation (ASTMD1143, ASTM D3689, ASTM D3966) of pressure, tension and horizontal load on single screw foundations. Performed by Applied Foundation Testing (AFT), USA, and CLTTHOMPSON INC, USA.
- NIRAS capacity and soil calculations, verified by LPILE by Ensoft Inc.
Our engineering team can provide design documentation for any structure based on European Design Standards (Eurocodes 0-9) and national annexes. Calculations can also be based on applicable American and Australian Design Standards.
Interested in our qualifications?
With our extensive knowledge of steel structures, we are happy to advise you on your upcoming construction project.
Please contact us if you need advice or would simply like to hear more about our expertise and business areas.